Fuel Piping and Fire Risk
Claims related to fires and explosions on vessels, show that nearly 60% originate in the engine room. Two thirds of these occurred on the main engine and auxiliary associated components. The majority of these incidents are caused by a failure in the low-pressure fuel piping, allowing spray onto an unprotected hot surface. Pipe fatigue due…
Read MoreAmps – Engine Starting v Auxiliary Loads
When a battery is regularly charged and discharged it causes deterioration of the positive plate. Plate thickness varies widely and so cannot be used as an indication of capacity. For example, a high performance engine starting battery with 22 plates per cell is available and is approximately 65 ampere hours in capacity, whilst another battery…
Read MoreBattery Do’s and Do Not’s
Insufficient charging voltage will cause poor battery performance. Insufficient charging voltage will cause short battery life. Excessive charging voltage will cause short battery life. Leaving a battery partially charged will reduce life and performance. Periodically batteries need to be fully charged to maximize life and performance. Engine Starting Batteries are required to deliver high current…
Read MoreHigh Cranking Amps v Amp Hour Capacity
Engine starting batteries are required to provide a very high cranking current for a short time. After this the battery simply receives charge from the alternator. To achieve high cranking current output, the manufacturer uses very thin plates made in such a way that the acid has good access to the active material which is…
Read MoreBattery Temperature and Charge/Discharge
A hot battery requires lower charge voltage to receive the correct charging current, so a lower charge voltage should be applied as the temperature increases – this is called temperature compensation. Any chemical device (the activity inside the battery) is affected by temperature. The gradual deterioration of the lead based grid/plate by this electro-chemical action is…
Read MoreWhy High Charge Voltage is Important
If a battery is left flat or partially charged it develops a sludge between the lead plates called ‘Lead Sulphation’, this slows the current flow during recharge. This condition is similar to ‘sludge’ in a water tank which builds the back pressure lessening inward flow. It can render a battery useless, reducing capacity and making…
Read MoreBattery Ventilation and Float Charge
When the battery nears full charge bubbles of hydrogen and oxygen gas leak out the battery by way of vent plugs. This is normal but does require batteries are placed in a ventilated space. Some ‘sealed/no maintenance’ types of batteries do not produce gas in normal working conditions, but if overcharged by a faulty charge…
Read MoreBattery DC and Water Flow Similarities
DC Battery electrics are similar to water and flow through pipework. A battery or storage tank has a positive/water pressure out and negative pressure in. An alternator/charger is simply an electrical pump refilling the tank, the alternator/charger usually has a pressure/charge regulator. The alternator/water pressure needs to have higher pressure than the tank/battery or it…
Read MoreCharging Times for Batteries
In electrical systems, volts are the electrical pressure and the electrical flow is the amps. The flow is dependent upon the restrictions in the electrical circuit called resistance. Batteries merely store power – volts and amps = current. If the battery is not charged at the right pressure (volts) or does not receive adequate charge…
Read MoreCharge Regulation of Batteries
For electric current to enter a battery the voltage of the alternator/charger needs to be higher than the battery. If the voltage is too high the battery will be damaged through overcharging. With a fixed charge (i.e. unregulated) inward voltage the current flow needs to steadily taper downwards but not all alternators and chargers have…