Keith Butterfield, Yacht and Marine Surveyor. Costa del Sol, Spain.

Install a fixed-mount inverter no more than 3m from the battery bank, to avoid a voltage drop or extra large cables. Inverters are not ignition protected, so are not safe for installation in compartments with explosive battery gasses; they can be installed in a diesel engine space. In general, pick a location that is cool, dry, well ventilated.

Inverter efficiency is a rating of how much of the DC energy gets converted into usable AC power, ranging from about 85% to 95%, with 90% being about average. Efficiency ratings often are created using a resistive load (basically something like a light bulb or electric heater). When running loads such as motors, the efficiency is split into two parts, the efficiency of the inverter, and the efficiency of the waveform. Waveform efficiency means that most motors and electronic appliances run better and use less power with a pure sine wave. Typically, an electric motor (such as a pump or refrigerator) will consume from 15% to 20% more power with a modified sine wave.

The charger in an inverter/charger presents a large, inductive load for a small generator (under 8kW). Chargers with a high “power factor” are desirable because they are less sensitive to peak voltage and need less AC power.