Keith Butterfield, Yacht and Marine Surveyor. Costa del Sol, Spain.
Manuals, Signs, Notices: Typical signs and notices to be provided. Prepare the following:
Prepare IMO type Fire & Safety Plan showing locations of all firefighting and safety equipment. Sticker pack is available from RYA (I think). Post at wheelhouse
Prepare Station Bill including abandon ship procedure and responsibilities of crew and passengers. Post at galley
Radio distress procedure (of type provided by any coastguard) to be posted at wheelhouse and noting Call Sign and MMSI
2 x SOLAS No. 2 cards to be posted at wheelhouse so that both sides show
A file of instructions for use of the lifesaving appliances (manufacturers instructions) to be maintained at wheelhouse
Engine room hatch/weather door to remain closed when machinery operating. Sign to be installed; ‘Weather door and Hatch to remain closed when machinery operating’
Engine room door to be provided with sign: ‘Engine Room Authorised Personnel Only. Door to Remain Closed When Machinery Operating. Hearing Protection Required’
Sign to be prepared with instructions for discharge of CO2 system. To be posted next to activator. To include instructions to close engine room blowers, shut down engines, close engine room doors and evacuate engine room prior to release
Engine room door to have sign – ‘This area protected with CO2 firefighting system. Evacuate engine room when alarm sounds’