Keith Butterfield, Yacht and Marine Surveyor. Costa del Sol, Spain.

In the minds of most manufacturers and boat owners, bilge pumps serve as emergency pumps. There are enough holes through the average boat to sink it in minutes. Boat flooding due to poorly maintained through-hull components are consistently a leading cause of insurance claims.

Do not assume the manufacturer has sized the bilge pump to handle an emergency. A surprisingly large amount of water will enter through the smallest of holes. Aided by pressure a 12mm hole at 30cm below waterline allows 25 litres of water per minute into the hull. Increase that to a 25mm hole at 1 meter below and you can expect 200 litres per minute.

Many bilge pumps are undersized to perform as emergency pumps. A pumps capacity is reduced by how high the pump must lift water above the level of the pump; then there is voltage loss in the electric cables; and then friction resistance in the length of pipework from the bilge pump to the outside hull. For example: A 12 volt 2500 litre per hour pump can lose 20% voltage drop from the nominal 12v in the battery due to cable length to the bilge area – this costs 500 litres; then static head loss for just 90cm loses a further 750 litres; then an 18mm pipe diameters resistance over its length loses a further 20% – 500 litres. The net result is that only 750 litres per hour is pumped from the bilge. Better to install or carry a high-volume de-watering pump for emergencies.