Keith Butterfield, Yacht and Marine Surveyor. Costa del Sol, Spain.
A slow rate of flooding should be managed by a fitted bilge pump. The connected float switch is intended to automatically activate the pump. The pump, wiring, and switch will then be partially submerged at the time of flooding. Electrical connections without protection from water or moisture may prevent the pump from working.
Bilge pumps can fail in months rather than years, especially in contaminated bilges. After any partial flooding, it is important to check and/or replace batteries, pumps, and wiring. Even if still working – wiring exposed to salt water makes further failure imminent.
ISO 13297 states that “Current carrying conductors shall be routed above areas where water can accumulate.” If that is not possible (as with bilge pump wiring), “wiring and connections shall be in enclosures conforming to IEC 60529:1989 – IP67, as a minimum, and there shall be no connection below the foreseeable water level.” Whilst ISO 13297 is not obligatory for most small vessels, it describes the bare minimum of common-sense good practice for a bilge pump installation – as it is self-evident that a pump will fail once unprotected electrical connections are submerged. Clamped, crimped and/or taped connections have no moisture protection.