Small electrically powered craft and other vehicles (such as personal watercraft) are becoming more commonly used in place of petrol on yachts. Whilst electric craft do not necessarily represent a greater fire risk than petrol, there are considerable differences in best practice for fire prevention, storage, fire detection and fire suppression when they are stored onboard. Where lithium-ion (Li-ion) batteries are used as the source of power, batteries with alternative internal chemistries present a different risk profile during charging or stowage.
There has recently been an average increase in the number of fires on yachts; one potential explanation for the unexplained increase in fires could be lithium-ion (Li-ion) batteries. There has been an increase in the use of small electric tenders, electric jet skis, electric foils (e-foils) and other craft powered by Li-ion batteries. However, there has not been a thorough consideration of whether the fire prevention, detection and suppression measures previously in-place on large yachts are appropriate for the newer-battery powered craft.
A review of hull and machinery claims related to fires and explosions on vessels, shows that nearly 60% of all fires onboard originated in the engine room or garage where Li-ion were stored or being charged. Whilst nearly two thirds of these fires occurred on the main and auxiliary engines or associated components, with the majority caused by a failure in the flammable fuel low-pressure piping, around 40% remained unresolved with Li-ion battery charging being considered suspect and traditional fire prevention, detection, suppression systems, and storage of batteries being inadequate to the task.